Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008).
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
ASTM D-4052
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
oscillating densitimeter
Key result
Type:
relative density
Density:
1.116 g/cm³
Temp.:
20 °C

Table 1 - Density, Specific Gravity and Density Temperature

Sample Name

Density (g/cm³)

Specific Gravity

Density Temperature (°C)

8055065-1

1.11585

1.11786

20.01

8055065-2

1.11586

1.11787

20.01

8055065-3

1.11587

1.11788

20.01

average

1.11586

 

 

Standard Deviation

0.00001

 

 

Conclusions:
A density value of 1.1159 g/cm3 at 20°C was determined for the substance in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.

Description of key information

Density: 1.1159 g/cm3 at 20°C (ASTM D4052)

Key value for chemical safety assessment

Additional information

A measured density value of 1.1159 g/cm3 at 20°C has been determined for the substance using an appropriate test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.