Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
sensitisation data (humans)
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented publication which meets basic scientific principles

Data source

Reference
Reference Type:
publication
Title:
Pulmonary retention of lead: an experimental study in man
Author:
Morrow PE, Beiter H, Amato F & Gibb FR
Year:
1980
Bibliographic source:
Environmental Research 21(2):373-384

Materials and methods

Type of sensitisation studied:
respiratory
Study type:
study with volunteers
Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of 12 2-in. scintillation detectors and two 2-in. leg counters, all coupled to single channel analyzers.
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Lead hydroxide
EC Number:
243-310-3
EC Name:
Lead hydroxide
Cas Number:
19783-14-3
Molecular formula:
H2O2Pb

Method

Type of population:
general
Ethical approval:
confirmed and informed consent free of coercion received
Subjects:
- Number of subjects exposed: 2 groups of 4 and 5 persons each
- Sex: men
- Age: mean 26.5 (24-37)
- Other: mean weight 65.9 kg (55-86.4), mean height 1.75 m (1.65-1.85)
Clinical history:
Young adults having no history of pulmonary disease
Route of administration:
inhalation
Details on study design:
TYPE AND DETAILS OF TEST(S) USED
- Lung function measurements: standard respiratory mouthpiece, deszigned so that the aerosol volume breathed was continuously measured using a recording integrator (Linear Instruments, Model 252A)
- Other: the exposure duration was predicated on the assumption that 100% deposition would occur

Results and discussion

Results of examinations:
The average aerosol deposition occuring in the nine lead hydroxide exposures was 26% (SD = 8). This resulted in 1.9 µCi 203Pb (0.7-3.2) and ~3 (1-5) micrograms of lead being deposited in the respiratory system of the average subject.
The measured (effective) halftime for retention of 950min (15.8h) for indicates a biological retention halftime of 22.6 h. Thus the correction factor reduces the biological half time approximately 40% (13.6 vs 22.6).

Any other information on results incl. tables

Urban air studies indicate atmospheric lead aerosol has a MMAD between 0.18 and 0.6 µm

Applicant's summary and conclusion

Conclusions:
The collective evidence supports the view that atmospheric lead is rapidly and completly absorbed from the human lungs.