Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
other: Endpoint Assessment Report: Oxidising Properties
Adequacy of study:
key study
Study period:
March 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Qualifier:
no guideline required
Principles of method if other than guideline:
- Principle of test: A screening procedure has been used to assess the oxidising properties of Aryl sulphonate condensate
- Short description of test conditions: Procedure takes into consideration the following: Annex VII of the REACH regulation ((EC) No 1907/2006), section 7.13; Section 2.14.4.1 of the CLP regulation; Section 2.14.4.2 of the CLP regulation.
- Parameters analysed / observed: Oxidising properties
GLP compliance:
no
Key result
Sample tested:
other: Endpoint assessment
Parameter:
other: Endpoint assessment: Oxidising properties.
Remarks on result:
other: No oxidising properties.
Interpretation of results:
GHS criteria not met
Conclusions:
For the Endpoint Assessment: Oxidising properties the structural assessment of Aryl sulphonate condensate reported that it is not expected to possess oxidising properties.
Executive summary:

In this Endpoint Assessment a structural assessment of Aryl sulphonate condensate was conducted to determine its oxidising properties. This was achieved through the use of a screening procedure which was used to assess the oxidising properties of Aryl sulphonate condensate, taking the following into consideration: Annex VII of the REACH regulation ((EC) No 1907/2006), section 7.13; Section 2.14.4.1 of the CLP regulation; Section 2.14.4.2 of the CLP regulation. The conclusion of this report was that based on the structural properties of Aryl sulphonate condensate it is not expected to possess oxidising properties.

Description of key information

In this Endpoint Assessment a structural assessment of Aryl sulphonate condensate was conducted to determine its oxidising properties. This was achieved through the use of a screening procedure which was used to assess the oxidising properties of Aryl sulphonate condensate, taking the following into consideration: Annex VII of the REACH regulation ((EC) No 1907/2006), section 7.13; Section 2.14.4.1 of the CLP regulation; Section 2.14.4.2 of the CLP regulation. The conclusion of this report was that based on the structural properties of Aryl sulphonate condensate it is not expected to possess oxidising properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification