Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO No., other:
Principles of method if other than guideline:
Flash Point by Closed cup method Pensky-Martens apparatus
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): 4-sulphoanthranilic acid
- Substance type: Organic
- Physical state: Solid

Results and discussion

Flash point
Atm. press.:
975 hPa
Remarks on result:
other: Non Flammable

Applicant's summary and conclusion

Executive summary:

In accordance with Section 2 of REACH Annex XI, information requirement section 7.9, this study does not need to be conducted based on the physical state of the molecule. According to ECHA guidance, flash point is only relevant to liquids and low melting point solids. Moreover the experimental data indicates that the substance did not ignite and so flash point not applicable for 4-sulphoanthranilic acid.