Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 93 procedure B
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
acetalization product between glucose and C14 alcohol
EC Number:
923-418-3
IUPAC Name:
acetalization product between glucose and C14 alcohol
Details on test material:
- Name of test material (as cited in study report): Montanov 14
- Substance type: UVCB
- Physical state: solid
- Analytical purity: >99%

Results and discussion

Flash point
Flash point:
ca. 166 °C
Atm. press.:
ca. 1 013 hPa

Any other information on results incl. tables

This study is performed in SEPPIC analytical laboratory and following the standard method.

This chemical has a Flash Point equal to 166°C

Applicant's summary and conclusion

Conclusions:
Flash point is 166°C
Executive summary:

This study is performed in SEPPIC analytical laboratory and following the standard method.

This chemical has a Flash Point equal to 166°C