Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
no data
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test compliant with GLP and Guideline 79/831/EEC, 3.9 DIN 51758

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1988

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 79/831/EEC, 3.9, DIN 51758
Deviations:
not specified
GLP compliance:
yes
Type of method:
other: DIN 51758

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
165 °C
Atm. press.:
ca. 101.3 kPa
Remarks on result:
other: no data of atm. pressure is available, for TCC ca. 101.3 kPa filled in.

Applicant's summary and conclusion

Conclusions:
Flash point: 165°C