Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 439-730-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable gases
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- the study does not need to be conducted because the substance is a solid
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
- Endpoint:
- pyrophoric liquids
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- the study does not need to be conducted because the substance is a solid
- Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Endpoint:
- self-heating substances / mixtures
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- other:
Referenceopen allclose all
Description of key information
The substance has not to be classified as flammable gas, flammable liquid, flammable solid, pyrophoric solid, pyrophoric liquid, flammable in contact with water, flammable aerosol or self-heating substance.
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
Flammable solids (reference 4.13-1)
A preliminary test according to Regulation (EC) No 440/2008 method A.10 was performed to determine the flammability of the test substance. The test item was formed into a powder train. The flame from a gas burner was applied to one end of the powder train for 2 minutes. The burning of the pile was observed. The test was performed twice. In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed. The test item is considered as a not readily combustible solid of Division 4.1. and is not a flammable solid.
Flammable gases (reference 4.13-2)
The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.
Flammable liquid (reference 4.11-1)
The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as flammable liquid.
Pyrophoric liquids (reference 4.13-3)
The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as pyrophoric liquid.
Pyrophoric solids (reference 4.13-4)
In accordance with section 2.9.4 Annex I of Regulation (EC) No 1272/2008 and ECHA guidance on the application of CLP Criteria section 2.10.4.2 the classification procedure for pyrophoric solids need not be applied when experience in manufacturing or handling shows that the substance or mixture does not ignite spontaneously when coming into contact with air at normal temperatures. Based on the experience in handling and use the substance is not known to ignite spontaneously when coming into contact with air at normal temperatures. Thus, no study was conducted and the substance was not considered for classification as pyrophoric solid.
Self-heating substances/mixture (reference 4.13-5)
In accordance with column 2 of REACH Annex VII and ECHA guidance on IR/CSA chapter R7a, the self-heating study does not need to be performed if preliminary results exclude self-heating of the substance up to 400°C. The test item was determined to be not self-igniting up to 400 °C under the test conditions of EU A.16. Thus, the test UN N.4 for self-heating substances was omitted as self-heating can be excluded.
Substances which, in contact with water, emit flammable gases (reference 4.13 -6)
In accordance with column 2 of REACH Annex VI and with Regulation (EC) No 1272/2008 Annex I section 2.12.4.1(b) the classification procedure for this hazard class need not to be applied. Based on the experience in handling and use the substance does not react with water and in addition the test substance is not pyrophoric. Thus, no study was conducted and the substance was not considered for classification.
Flammable Aerosols
Section 2.4.2 of Guidance on the application on the CLP Criteria states as follows: “Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state." Thus, as the substance does not meet the definition for aerosol because it is a solid substance, the test for aerosols was waived. Consequently the substance has not to be considered for classification for this hazard class.
In conclusion the test substance has not to be considered as flammable gas, flammable liquid, flammable solid, flammable in contact with water, flammable aerosol, pyrophoric solid, pyrophoric liquid or self-heating substance
Justification for classification or non-classification
Classification, Labelling, and Packaging Regulation (EC) No. 1272/2008
In accordance with Annex I section 2.2, section 2.3, section 2.6, section 2.7, section 2.9, section 2.10, section 2.11 and section 2.12 of Regulation (EC) No 1272/2008, as amended for the twelfth time in Regulation (EU) 2019/521, and UN GHS Rev 7 (2017) the test item has not to be classified as flammable liquid, readily combustible solid in class 4, Division 4.1, self-heating substance in Class 4, Division 4.2, substance which in contact with water emits flammable gases in Class 4, Division 4.3, pyrophoric liquid, pyrophoric solid in class 4, Division 4.2, flammable gas in class 2 or as aerosol in class 2.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.