Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study Experimental phase 2013-05-10 to 2013-05-23. Report complete 2013-06-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria for classification as reliable without restriction according to Klimisch et al (1997).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
lithium 3-((3,4-dicyanophenyl)thio)propane-1-sulfonate
EC Number:
700-787-7
Cas Number:
769953-18-6
Molecular formula:
C11H9N2O3S2Li
IUPAC Name:
lithium 3-((3,4-dicyanophenyl)thio)propane-1-sulfonate
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks on result:
other: The test material failed to ignite during the 2 minute application of the Bunsen burner to the pile of test material

Any other information on results incl. tables

Preliminary Screening Test

The pile failed to ignite during the two minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable
Conclusions:
The test material was determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Introduction

This test was undertaken to determine the flammability (solids) of the test material. Testing was conducted using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Results & Conclusion

The pile of test material failed to ignite during the 2 minutes that the Bunsen Flame was applied to it. The result of the preliminary screening test obviated the need to perform the main test. The test material was determined to be not highly flammable as it failed to ignite in the preliminary screening test.