Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied
Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied

Description of key information

Flammability:
In accordance with section 2 of REACH Annex XI, a study is technically not feasible as the substance is a liquid. The flammability of a liquid is described by the flash point.
Contact with water:
The flammability of a substance on contact with water is determined following the methods N.5 (UN-Manual of testing) or A.12 (EU-method).
However, in accordance with section 1 of REACH Annex XI, a study does not need to be conducted as it is scientifically unjustified. The structural composition of the test item contains none of the functional groups quoted in Manual of Tests and Criteria, appendix 6, article 5.3).
Pyrophoric properties:
Pyrophoric properties are determined following the methods N.3 (UN-Manual of testing) or A.13 (EU-method).
However, in accordance with section 1 of REACH Annex XI, a study does not need to be conducted as it is scientifically unjustified. Experience in the performance of other tests show that the substance does not ignite spontaneously on coming in contact with air at normal temperatures.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The substance is not yet classified in the Annex I of Directive 67/548/EEC. According to the information summarized in this below, no classification on flammability is needed:

- As liquid, no flash point up to 214.5 °C;

- As liquid, boiling point is higher than 300 °C;

- No pyrophoric property, based on experience from production and handling;

- It does not ignite spontaneously with water and does not liberate flammable gases in hazardous amounts in contact with water.

Based on the data summarized above, the substance is also not flammable according to GHS (Regulation EC 1272/2008).