Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
2009
Qualifier:
according to
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Version / remarks:
1996
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
< 0.002 Pa
Temp.:
25 °C
Vapour pressure:
< 0.007 Pa

Applicant's summary and conclusion