Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
ca. 236 °C
Decomposition:
yes
Decomp. temp.:
>= 300 °C

Any other information on results incl. tables

stainless steel crucible

30350°C – 2°C/min

Applicant's summary and conclusion

Conclusions:
Melting point by differential scanning calorimetry ca 236°C