Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Remarks on result:
no flash point according to standard method
Interpretation of results:
GHS criteria not met
Conclusions:
Pensky Martens by ASTM Method D93. Flash point = None. No flash observed up to 156⁰C (313⁰F).

Description of key information

No flash observed up to 156⁰C (313⁰F).

Key value for chemical safety assessment

Additional information