Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 934-405-7 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02/06/2015 - 05/06/2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 015
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - Shake Flask Method)
- Version / remarks:
- Preliminary test
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- estimation method (solubility ratio)
- Partition coefficient type:
- octanol-water
Test material
- Test material form:
- solid: particulate/powder
Constituent 1
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 040802#
Study design
- Analytical method:
- other: the preliminary test result showed that no complementary test was possible (HPLC method cannot be used)
Results and discussion
Partition coefficient
- Key result
- Type:
- log Pow
- Partition coefficient:
- ca. -4.9
- Remarks on result:
- other: estimated value because the test item remained undissolved into octanol up to the concentration limit
Any other information on results incl. tables
Estimation of partition coefficient |
|
Octanol Sample Preparation Approximately 2 mg of X330 was added to a 40 mL clear glass vial, followed by Octanol 40 mL. The sample was shaken, sonicated and warmed to approximately 40°C. The sample remained undissolved. The preparation above was repeated using 0.40 mg of X330. The second X330 sample remained undissolved. At concentrations below 10 mg/L it was difficult to accurately determine the presence X330. Therefore it is not known if the sample is soluble below this concentration or if this is the limit of detection for the visualisation of X330 in octanol.
.
Applicant's summary and conclusion
- Conclusions:
- The estimated partition coefficient Log Pow = -4.9.
- Executive summary:
The partition coefficient was estimated using the shake flask method according to the EU A.8 test guideline. The estimated value was: Log Pow = -4.9
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
This website uses cookies to ensure you get the best experience on our websites.
Find out more on how we use cookies.