Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17/04/2015 โ€“ 29/04/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:040802#
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: For the test of mechanical sensitivity with respect to shock, (with a BAM Fallhammer apparatus) and the test of mechanical sensitivity with respect to friction ( (BAM friction apparatus), the test item is sieved at 0.5 mm (fraction test used < 0.5 mm). For the test of thermal sensitivity (Koenen tube test), the test item is used as received.
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Value:
40
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Value:
360
Remarks on result:
not sensitive to friction using a friction load of 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
6
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Value:
2
Remarks on result:
not thermal sensitive if heated under defined confinement
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is considered has insensitive to heat, shock nor friction.
Executive summary:

The explosiveness properties were determined by a serie of 3 tests according to the EU A.14 test guideline.

  • The test of thermal sensitivity was performed with a Koenen tube in triplicate for each diameter orifice plate (6 mm and then 2 mm). The test item did not exhibit an explosion during any of the tests. The test result is therefore considered negative.
  • The test of mechanical sensitivity with respect to shock was performed on a test item sieved 0.5 mm prior to testing, using a BAM Fallhammer device and a series of 6 tests was performed dropping a 10 kg mass from 0.40 m (40 J). The test item exhibits no reaction at 40 J. The test result is therefore considered negative.
  • The test of mechanical sensitivity with respect to friction was performed on a test item sieved 0.5 mm prior to testing, using a BAM friction device and a series of 6 tests was performed with a load of 360 N. The test item exhibits no reaction at 360 N. The test result is therefore considered negative.

As a conclusion, The substance is considered has insensitive to heat, shock nor friction.

Description of key information

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

  • Test of thermal sensitivity (Koenen tube) in triplicate: no explosion during any of the tests. The test result is therefore considered negative.
  • Test of mechanical sensitivity with respect to shock (BAM Fallhammer device) series of 6 tests: no reaction at 40 J. The test result is therefore considered negative.