Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Data is from experimental study
Qualifier:
according to guideline
Guideline:
other: DIN 66165
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Mass median aerodynamic diameter:
1 680 µm
Key result
Percentile:
D10
Mean:
890 µm
St. dev.:
0
Key result
Percentile:
D50
Mean:
1 680 µm
St. dev.:
0
Key result
Percentile:
D90
Mean:
2 016 µm
St. dev.:
0
No.:
#1
Size:
< 63 µm
Distribution:
0.5 %
No.:
#2
Size:
>= 63 - <= 125 µm
Distribution:
1.6 %
No.:
#3
Size:
>= 125 - <= 250 µm
Distribution:
3.6 %
No.:
#4
Size:
>= 250 - <= 500 µm
Distribution:
6.3 %
No.:
#5
Size:
>= 500 - <= 1 000 µm
Distribution:
11 %
No.:
#6
Size:
>= 1 000 - <= 1 400 µm
Distribution:
16.6 %
No.:
#7
Size:
> 1 400 µm
Distribution:
100 %
Conclusions:
The test item has particle size of : D10 = 890 µm, D50 = 1680µm and D90 = 2016µm. MMAD = 1680µm
Executive summary:

The test item has particle size of : D10 = 890 µm, D50 = 1680µm and D90 = 2016µm. MMAD = 1680µm

Description of key information

The test item has particle size of : D10 = 890 µm, D50 = 1680µm and D90 = 2016µm. MMAD = 1680µm

Additional information

The test item has particle size of : D10 = 890 µm, D50 = 1680µm and D90 = 2016µm. MMAD = 1680µm.

In another experimental study report, the particle size distribution of test item was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was determined to be in the range of 150 micron to 53 micron.