Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
> 105 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C
Interpretation of results:
GHS criteria not met
Conclusions:
flash point > 105C
Executive summary:

The method used was ASTM D3278.

the substance boiled around 103C and the flame was extinguished (by steam?) Above 103C, the flame was still not sustainable despite re-ignition. The study was stopped at 106C with no flash being observed.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion