Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid having a melting point <= 160°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
no GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
no
Type of method:
capillary method
Key result
Melting / freezing pt.:
112 - 114 °C
Atm. press.:
1 atm
Decomposition:
no
Conclusions:
The experimental determined melting range of the test substance is 112-114 °C.
The study was performed according to OECD TG102 with restrictions (e.g. no GLP) and therefore reliability of Klimisch 2 has been assigned.
Executive summary:

The melting range of the test material Pyridine-2-carbaldehyde oxime was determined experimentally to be 112 -114°C using the capillary method in a non-GLP test according to OECD guideline 102 .

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion