Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 01, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Reference:
Composition 0
Principles of method if other than guideline:
Laser light scattering. The test was performed according to the SOP - STR 071 (Hydro 2000S) protocol.The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the size of particles. It measures the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Test material information:
Composition 1
Percentile:
D10
Mean:
ca. 2.844 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment
Percentile:
D50
Mean:
ca. 10.798 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment
Percentile:
D90
Mean:
ca. 35.6 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment

After 2 minutes of ultrasonic treatment

Conclusions:
D10 = 2.844 µm
D50 = 10.798 µm
D90 = 35.600 µm
Executive summary:

Method

The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the intensity of light scattered as a laser beam going through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that create the scattering pattern.

Result

Analysis carried out after 2 minutes of ultrasonic treatment:

D10 = 2.844 µm

D50 = 10.798 µm

D90 = 35.600 µm

Description of key information

MMD = 10.798 µm

Additional information

Laser light scattering method