Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-01-15 to 2015-01-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
Batch No 1507511210
Key result
Temp.:
ca. 20 °C
Vapour pressure:
< 0 Pa
Key result
Temp.:
ca. 25 °C
Vapour pressure:
< 0 Pa
Key result
Temp.:
ca. 50 °C
Vapour pressure:
< 0 Pa
Executive summary:

The vapour pressure of the test item was determined according to the following guidelines: European Commission Regulations (EC) No. 761/2009, A.4. Vapour pressure: Effusion method and OECO test guideline, OECD 104.

Based on the detection limit of the vapour pressure measurement at 90 °C (1 * 10-5 hPa), the following upper limit vapour pressure values for the test item were calculated:

20 °C: < 1* E-6 Pa

25 °C: < 1* E-5 Pa

50 °C. < 1* E-4 Pa

Description of key information

The vapour pressure of the test item was determined according to the following guidelines: European Commission Regulations (EC) No. 761/2009, A.4. Vapour pressure: Effusion method and OECO test guideline, OECO 104.

Based on the detection limit of the vapour pressure measurement at 90 °C, the following upper limit vapour pressure values for the test item were calculated:

20 °C: < 1* E-6 Pa

25 °C: < 1* E-5 Pa

50 °C. < 1* E-4 Pa

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information