Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Conducted at GLP-accredited facility to current guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Test was performed with sample Lot number: DF 2334

Results and discussion

Flash point
Flash point:
ca. 137 °C
Atm. press.:
ca. 101.53 kPa

Applicant's summary and conclusion

Conclusions:
The flash pointof the test material has been determined to be 137 +/- 2 °C.
Executive summary:

The flash pointof the test material has been determined to be 137 +/- 2 °C.