Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Conducted at GLP-accredited facility to current guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM E537-86, Method A2 of Commission Directive 92/69/EEC
Deviations:
no
Principles of method if other than guideline:
ASTM E537-86, Method A2 of Commission Directive 92/69/EEC
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Test was performed with sample Lot number: DF 2334

Results and discussion

Boiling point
Boiling pt.:
ca. 569 K
Atm. press.:
ca. 101.08 kPa
Remarks on result:
other: measured under nitrogen atmosphere

Applicant's summary and conclusion

Conclusions:
Boiling temperature: 569 +/-0,5 K at 101,08 kPa, by differential scanning calorimetry, using ASTM E537-86, Method A2 of Commission Directive 92/69/EEC
Executive summary:

Boiling temperature: 569 +/-0,5 K at 101,08 kPa, by differential scanning calorimetry, using ASTM E537-86, Method A2 of Commission Directive 92/69/EEC