Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted according to internationally accepted testing procedure
Principles of method if other than guideline:
The test was performed according to the SOP - STR 071 protocol.
Laser light scattering.
The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measures the size of particles. It measures the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern.
The sample was dispersed, stirred and ultrasonicated prior the analytical characterisation by light scattering.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Key result
Percentile:
D10
Mean:
ca. 1.406 µm
St. dev.:
2
Key result
Percentile:
D50
Mean:
ca. 6.597 µm
St. dev.:
5
Key result
Percentile:
D90
Mean:
ca. 27.85 µm
St. dev.:
5
Conclusions:
The substance particle size distribution was measured by light scattering and the results are D10 = 1.4 µm, D50 = 6.6 µm and D90 = 27.85 µm.
Executive summary:

The particle size distribution of the test substance was measured by light scattering and the results are D10 = 1.4 µm, D50 = 6.6 µm and D90 = 27.85 µm (Reach&Colours, 2015).

Description of key information

The particle size distribution was measured by light scattering (Reach&Colours, 2015).

Additional information

Value used for CSA:

The particle size distribution is as follows: D10 = 1.4 µm, D50 = 6.6 µm and D90 = 27.85 µm.