Registration Dossier

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From December 16, 2015 to March 9, 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
6
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Parameter:
sensitiveness to impact: impact energy (J)
Value:
40
Number of fragments:
0
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
sensitiveness to friction: friction load (N)
Value:
360
Number of fragments:
0
Remarks on result:
not sensitive to friction using a friction load of 360 N

Table 1. Thermal sensitivity test

Serials

Mass of sample

(g)

Diameter of orifice

(mm)

Fragment effect of tubes

Test results

1

24.05

6.0

O

No explosion

2

23.09

6.0

O

No explosion

3

23.58

6.0

O

No explosion

4

23.50

2.0

B

No explosion

5

23.36

2.0

D

No explosion

6

23.18

2.0

B

No explosion

O: Tube unchanged

B: Bottom and wall of the tube bulged out

D: Wall of tube split

Table 2. Shock sensitivity test

Serials

Drop weight

(kg)

Drop height

(cm)

Impact energy

(J)

Test results

1

10

40

40

No reaction

2

10

40

40

No reaction

3

10

40

40

No reaction

4

10

40

40

No reaction

5

10

40

40

No reaction

6

10

40

40

No reaction

Table 3. Friction sensitivity test

Serials

Weight number

Notch number

Friction load/N

Test results

1

9

VI

360

No reaction

2

9

VI

360

No reaction

3

9

VI

360

No reaction

4

9

VI

360

No reaction

5

9

VI

360

No reaction

6

9

VI

360

No reaction

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.14 test method, CJ302 was not considered to present a danger of explosion.
Executive summary:

The explosive properties of CJ302 was determined according to EC REGULATION No 440/2008 Annex A.14 explosive properties. CJ302 does not present a danger of explosionin the thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore, CJ302 was not considered to present a danger of explosion.

Description of key information

CJ302 was not considered to present a danger of explosion (EC A.14).

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

CJ302 does not present a danger of explosionin the thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore, CJ302 was not considered to present a danger of explosion.

Justification for classification or non-classification