Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 June 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction; ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
other: Laser Diffraction Methods
Specific details on test material used for the study:
Lot. AT-0032668200
Percentile:
D10
Mean:
0.961 µm
Remarks on result:
other: St. dev. is not specified
Percentile:
D50
Mean:
2.475 µm
Remarks on result:
other: St. dev. is not specified
Percentile:
D90
Mean:
24.26 µm
Remarks on result:
other: St. dev. is not specified
Conclusions:
Median particle size of FAT 20035/E is 2.475 μm.
Executive summary:

The purpose of the study was the evaluation of the particle size distribution for he test substance FAT 20035/E, according to the following guidelines CIPAC MT 187: Particle Size Analysis by Laser Diffraction ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods.


 


Particle size of FAT 20035/E are as follows:


L10: 0.961 μm


L50 (median particle size): 2.475 μm


L90: 24.260 μm

Description of key information

Median particle size of test substance is 2.475 μm. 

Additional information

A study was performed to evaluate the particle size distribution for the test substance FAT 20035/E, according to the CIPAC MT 187: Particle Size Analysis by Laser Diffraction, ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods.


Median particle size (L50) of FAT 20035/E is found to be 2.475 μm.