Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Valid method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report Date:
2002

Materials and methods

Principles of method if other than guideline:
Differential scanning calorimetry (DSC)
Type of method:
thermal analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Decomposition:
yes
Decomp. temp.:
>= 330 °C

Any other information on results incl. tables

No melting point was observed. Decomposition (with a mean energy of -780 J/g from several measurements) starts above 330 °C.

Applicant's summary and conclusion

Conclusions:
The test substance decomposes above 330 °C.
Executive summary:

The thermal behaviour of the test substance was determined with Differential Scanning Calorimetry (DSC) measurements. No melting was observed. Decomposition started above 330 °C.