Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
not specified
Key result
Test procedure:
burning rate test over 100 mm length
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
2-chlorbenzonitrile (solid) doesn't ignite, but melts.
The melt doesn't ignite.
Executive summary:

A continuous fill in triangular form with a height of 10 mm and a width of 20 mm is placed on a non-flammable surface.

The fill is ignited with a gas burner within 2 minutes.

It has to be determined weather the combustion propagates over a length of 200 mm within 4 minutes.

2-chlorbenzonitrile (solid) doesn't ignite, but melts.

The melt doesn't ignite.

Description of key information

The substance 2 -Chlorobenzonitrile can't be ignited with the Flame of a gas burner.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The substance can't be ignited with the flame of a gas burner.

It is therfore not classified as flammable.