Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Guideline:
other: UN, Part III, Test N.1, Section 33.2.1.4
Principles of method if other than guideline:
Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, 2nd revised edition, Part III, Test N.1, Section 33.2.1.4
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): 4-Chlorphenylhydrazin
- Analytical purity: 97.8g/100g

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 120 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

1. Preliminary test:

Burning time ( 200 mm test distance): Burning time > 2 min, no metal powder. Therefore,

the preliminary screening test is negative.

Because of the result of the preliminary test the test substance is not considered a flammable solid of division 4.1.

Applicant's summary and conclusion