Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with standard testing method however not under GLP.
Principles of method if other than guideline:
Flash point measured in closed cup
GLP compliance:
no
Type of method:
other: Pensky-Martens in closed-cup
Key result
Flash point:
130 °C
Atm. press.:
1 atm
Conclusions:
The reported flash point is 130°C.
Executive summary:

The measured flash point of the substance Isoeicosane is 130°C (PMcc method).

Description of key information

The flash point of Isoiecosane, measured following Pensky-Martens closed cup method, is 130°C (company data).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
130 °C

Additional information