Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with standard testing method however not under GLP.
Qualifier:
according to guideline
Guideline:
other: ASTM D-445
Principles of method if other than guideline:
kinematic viscosity measured using certified reference standards. Time determined for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer at a specified temperature.
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
20.2
Conclusions:
The measured dynamic viscosity is 20.2 mPa.s at 20°C.
Executive summary:

The measured dynamic viscosity of Isoeicosane is 20.2 mPa.s at 20°C (company data).

Description of key information

The measured dynamic viscosity of Isoeicosane is 20.2 mPa.s at 20°C (company data).

Key value for chemical safety assessment

Viscosity:
20.2 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information