Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Being ignited with the flame of a teclu burner, the test item started to melt after a few seconds. Melting, but no ignition

was observed.

Therefore, the test item should be considered as not highly flammable.

Conclusions:
Not highly flammable.
Executive summary:

The test item does not ignit and is to be considered as not flammable.

Description of key information

not highly flammable

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The test item has not to be considered as flammable.

Justification for classification or non-classification

No classification due to result of experimental test