Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-03-19 to 2013-11-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: L-TME was assessed using particle size apparatus based on laser diffraction
Deviations:
not applicable
Principles of method if other than guideline:
The size distribution of particles was assessed using particle size apparatus based on laser diffraction
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl L-threoninate
EC Number:
222-158-1
EC Name:
Methyl L-threoninate
Cas Number:
3373-59-9
Molecular formula:
C5H11NO3
IUPAC Name:
Methyl (2S,3R)-2-amino-3-hydroxy-butanoate
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): L-threonine methyl ester
- Physical state: white crystalline powder
- Analytical purity: 99.8%
Specific details on test material used for the study:

SOURCE OF TEST MATERIAL
- Source and lot/batch number of test material: X5UYC99
- Expiration date of the lot/batch: July2014
- Purity test date: 99.8 %

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Frozen (ca. -20 ̊C)

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Preparation of a nanomaterial dispersion (incl. dilution):
A saturated solution of L-threonine methyl esterin heavydistillate of petroleum
The bulk container of test substance was inverted 10 times and a portion (500 mg) transferred to a vial. The entire contents of the vial were added directly to the sampling tank containing dispersant.

Results and discussion

Mass median aerodynamic diameter:
252 µm
Geometric standard deviation:
0
Remarks on result:
other: L-TME was determined to have d(0.1), d(0.5) and d(0.9) values of 63, 251 and 661 μm respectively. The Mass Median Diameter was determined to be 251 µm. No information on standard deviation.
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
63 µm
Remarks on result:
other: No information for Standard deviation.
Key result
Percentile:
D50
Mean:
251 µm
Remarks on result:
other: No information for Standard deviation.
Key result
Percentile:
D90
Mean:
661 µm
Remarks on result:
other: No information for Standard deviation.

Any other information on results incl. tables

L-TME was determined to have d(0.1), d(0.5) and d(0.9) values of 63, 251 and 661 μm respectively.

Applicant's summary and conclusion

Conclusions:
The particle size distribution of L-TME was determined to have d(0.1), d(0.5) and d(0.9) values of 63, 251 and 661 μm respectively.
Executive summary:

The size distribution of particles present in L-TME was assessed using particle size apparatus based on laser diffraction. L-TME was determined to have d(0.1), d(0.5) and d(0.9) values of 63, 251 and 661 μm respectively. The Mass Median Diameter was determined to be 251 µm