Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Feb 2014- April 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test)
Qualifier:
according to guideline
Guideline:
EU Method C.4-C (Determination of the "Ready" Biodegradability - Carbon Dioxide Evolution Test)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
tert-butyl 4-(6-aminopyridin-3-yl)piperazine-1-carboxylate
Cas Number:
571188-59-5
Molecular formula:
C14H22N4O2
IUPAC Name:
tert-butyl 4-(6-aminopyridin-3-yl)piperazine-1-carboxylate
Test material form:
solid: bulk

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, industrial (adaptation not specified)
Duration of test (contact time):
ca. 28 d
Initial test substance concentration
Initial conc.:
ca. 20 mg/L
Based on:
TOC
Reference substance
Reference substance:
other: Sodium acetate

Results and discussion

% Degradation
Key result
Parameter:
calculated rating of total degradation time (QSAR/QSPR)
Value:
ca. 2.21
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
LEE011-A2 was not readily biodegradable under the conditions of the modified Sturm test presently performed.