Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Feb 2014 - May 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
tert-butyl 4-(6-aminopyridin-3-yl)piperazine-1-carboxylate
Cas Number:
571188-59-5
Molecular formula:
C14H22N4O2
IUPAC Name:
tert-butyl 4-(6-aminopyridin-3-yl)piperazine-1-carboxylate
Test material form:
solid: bulk

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
<= 0 Pa
Key result
Test no.:
#2
Temp.:
ca. 25 °C
Vapour pressure:
<= 0 Pa

Applicant's summary and conclusion

Executive summary:

The isothermal TGA effusion method was applied for the determination of the vapour pressure of LEE011-A2.

The vapour pressure of the test substance at 20°C (293K) and 25°C (298K) was:

     Pa (20°C)    Pa (25°C)
   Test substance

  ≤ 9.5 × 10-6

 ≤ 2.1 × 10-5

The weight losses were obtained with a temperature program of above the melting temperature of the test substance and are therefore reported as ≤ values.