Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 915-372-8 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from 2016-03-07 to 2016-03-21
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Version / remarks:
- 2008
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.6315 (Flammability)
- Version / remarks:
- 1996
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D6450 - 12e1 Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D7094 – 12e1 Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: UN Handbook “Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria” Rev. 6, 2015, Method 32.4 “Test methods used for determining flash point and viscosity”
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- closed cup
- Flash point apparatus:
- Pensky-Martens apparatus
- Key result
- Flash point:
- 51 °C
- Atm. press.:
- 1 013.25 hPa
- Interpretation of results:
- Category 3 (flammable liquids) based on GHS criteria
- Conclusions:
- The flash point of the test item was determined to be 51 °C at 101.3 kPa.
- Executive summary:
A study was conducted according to Regulation (EC) No 440/2008 method A.9, ASTM D6450, ASTM D7094, ASTM D93 and OPPTS 830.6315 to determine the flash point of the test item using a closed cup method with Pensky-Martens apparatus. A screening test was performed with a search program to determine the rough flash point. For the main test about 2 g of the test item were filled in the cup. The first ignition trial of the main test was performed at a temperature range of 30 - 200 °C with heating rate of 5.5 °C/min. The test was performed three times. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be 51 °C at 1013.25 hPa.
Reference
The flash point of Dodecane was determined to be 79.4 °C, hardly deviating from the literature value (78.6°C, ASTM D 7094, Table X1.1).
For the determination of the initial temperature of flash point measurement a screen test was performed with the test item. The sample was heated from 30 °C to 200 °C (or to the flash point) using 5.5 °C/min heating rate. Based on this preliminary test the flash point of the test item was determined to be: 50.5 °C. In the course of the study three subsequent tests with the test item were carried out. The measured flash points of the test item were: 50.5 °C, 50.5 °C and 51.5 °C resulting a mean value: 51 °C at 101.3 kPa.
Description of key information
The flash point of the test item was determined to be 51 °C at 101.3 kPa.
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 51 °C
Additional information
A study was conducted according to Regulation (EC) No 440/2008 method A.9, ASTM D6450, ASTM D7094, ASTM D93 and OPPTS 830.6315 to determine the flash point of the test item using a closed cup method with Pensky-Martens apparatus. A screening test was performed with a search program to determine the rough flash point. For the main test about 2 g of the test item were filled in the cup. The first ignition trial of the main test was performed at a temperature range of 30 - 200 °C with heating rate of 5.5 °C/min. The test was performed three times. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be 51 °C at 1013.25 hPa.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.