Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
European Community (EC), EC no. 440/2008, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.10: “Flammability (Solids)”, Official Journal of the European Union no. L142, May 31, 2008.
United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Class 2, Class 3, Class 4, Division 5.1, Class 8 and Class 9, Test N.1: “Test Method for Readily Combustible Solids”, 2009.
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 4 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
No propagation of combustion of the test substance along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test substance is considered ‘not highly flammable’.

Any other information on results incl. tables

In contact with the flame of the gas burner the test substance melted, emitted yellow sparks and turned into a black residue. Grey smoke was observed. After removal of the ignition source, no propagation of combustion of the test substance was observed.

Applicant's summary and conclusion

Interpretation of results:
other: Not highly flammable
Conclusions:
The preliminary screening test was performed for the determination of the flammability of 1574 CETONA.
No propagation of combustion of the test substance along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test substance is considered ‘not highly flammable’.