Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 February 2013 - 26 April 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Version / remarks:
(1995)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
Version / remarks:
(1996)
Deviations:
no
GLP compliance:
yes
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl 3-aminopyrazinecarboxylate
EC Number:
240-387-5
EC Name:
Methyl 3-aminopyrazinecarboxylate
Cas Number:
16298-03-6
Molecular formula:
C6H7N3O2
IUPAC Name:
methyl 3-aminopyrazine-2-carboxylate
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): Amiloride Compound 6
- Description: Tan powder
- Storage condition of test material: In refrigerator (2-8°C) protected from light, desiccated
- Other: Reactive to light, moisture and oxygen

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficientopen allclose all
Type:
Pow
Partition coefficient:
1.5
Temp.:
20 °C
pH:
7
Remarks on result:
other: n=6. Standard deviation: 0.043
Type:
log Pow
Partition coefficient:
0.2
Temp.:
20 °C
pH:
7
Details on results:
The log Pow values were within the criterion range of ± 0.3 log units (see table below). Based on this, the Pow and log Pow of the test substance are given as the mean value of all measurements.

Any other information on results incl. tables

Results Shake flask method at pH 7

 

Ratio

n-octanol : water

[v:v]

Analysed concentration

Pow

log Pow

 

pH

 

n-octanol

[g/l]

Water

[g/l]

Individual

Mean

1:1

0.573

0.385

1.5

1.5

0.2

7.0

0.565

0.398

1.4

0.2

7.0

1:2

0.617

0.409

1.5

1.5

0.2

7.0

0.634

0.404

1.6

0.2

7.0

2:1

0.528

0.347

1.5

1.5

0.2

7.0

0.498

0.340

1.5

0.2

7.0

 

No test substance was detected in the pretreated samples from the blank mixture.

Applicant's summary and conclusion

Conclusions:
The log Pow of Amiloride Compound 6 at pH 7 and 20°C was determined to be 0.2 using the shake flask method (GLP-compliant study in accordance with EC A.8, OECD 107 and EPA OPPTS 830.7550).