Endpoint:
density, other
Remarks:
skeletal density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Cross-reference
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Principles of method if other than guideline:
To determine the Volumetric Particle Size Distribution using the Microtrac S3500 Particle Size Analyzer, a small amount of pigment along with 2-3 drops of Tamol SG-1 dispersant was added to the mixing tank. When the appropriate concentration was achieved, the ultrasonic probe turned on and the PSD analysis commenced. Three readings were taken, and the average was calculated. Reference: ASTM B822.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
2.8 µm
Geometric standard deviation:
1.1
Percentile:
D10
Mean:
1.4 µm
St. dev.:
1.1
Key result
Percentile:
D50
Mean:
2.7 µm
St. dev.:
11
Percentile:
D90
Mean:
4.4 µm
St. dev.:
1.1
Conclusions:
The test item has following particle size distribution:
mean = 2.8 µm
d90= 4.4 µm
d50= 2.7 µm
d10= 1.4 µm

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2022

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Principles of method if other than guideline:
To determine the skeletal density of the pigment by helium gas displacement, a sample was dried using an IR balance and then transferred to the Accupyc II 1340 Pycnometer. The instrument took three readings and the average was calculated. Reference: ASTM D5965 Test Method B.
GLP compliance:
no
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
Tricobalt bis(orthophosphate)
EC Number:
236-655-6
EC Name:
Tricobalt bis(orthophosphate)
Cas Number:
13455-36-2
Molecular formula:
Co3(PO4)2
IUPAC Name:
tricobalt bis(orthophosphate)
impurity 1
Chemical structure
Reference substance name:
Dicobalt diphosphate
EC Number:
238-689-7
EC Name:
Dicobalt diphosphate
Cas Number:
14640-56-3
Molecular formula:
Co2P2O7
IUPAC Name:
dicobalt diphosphate
impurity 2
Chemical structure
Reference substance name:
cobalt phosphate octahydrate
Cas Number:
10294-50-5
Molecular formula:
Co3(PO4)2.8H2O
IUPAC Name:
cobalt phosphate octahydrate
Test material form:
solid: particulate/powder
Dynamic viscosity of test material:
Not applicable: test material is a powder

Results and discussion

Density
Key result
Type:
other: skeletal density
Density:
3.8 g/cm³
Temp.:
120 °C

Applicant's summary and conclusion

Conclusions:
The skeletal density of the test item was determined to be 3.8 g/ cm³ at 120°C by a helium pycnometer.