Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
weight of evidence

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1998
Report date:
1998

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
Deviations:
no

Test material

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, adapted
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Based on:
test mat.

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
0
St. dev.:
0
Sampling time:
28 d
Remarks on result:
other:

Applicant's summary and conclusion

Validity criteria fulfilled:
no