Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: No deviation from A.9 guideline, GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: semi-solid at ambiant temperature
Details on test material:
The test item was semi-solid at ambient temperature; therefore it was necessary to heat it up to 90°C.

Results and discussion

Flash point
Flash point:
>= 141.2 - <= 143.2 °C
Atm. press.:
ca. 760 mm Hg

Applicant's summary and conclusion

Conclusions: