Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
no
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture 1:1
Parameter:
mean pressure rise time
Result:
42.68 s
Sample tested:
reference mixture 1: 1
Parameter:
mean pressure rise time
Result:
6.65 s
Conclusions:
The test item had no oxidizing properties under the test conditions in the sense of the Euroean Commission Regulation (EC) No. 440/2008, Method A.21.
Executive summary:

The oxidising properties of MC A45A was tested according to EU Method A.21.

Description of key information

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

The oxidising properties of MC A45A was tested according to EU Method A.21.

Justification for classification or non-classification