Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
190.5 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point was determined to 190.5°C under atmospheric conditions.
Executive summary:

The flash point of MC A45A was tested according to EU Method A.9.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
190.5 °C

Additional information

The flash point of MC A45A was tested according to EU Method A.9.