Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
21 AUG 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO No., other: 2719: 2007
Principles of method if other than guideline:
This method corresponds to A.9. Flash point.
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup method
Flash point:
143 °C
Atm. press.:
1 014 hPa
Remarks on result:
other: 143.0±2.9 (Uncertainity of the measurement)

Results of flash point measurements:

Number of test

Flash point [°C]

1

143.0

2

143.0

The lowest flash point

143.0

Result of determination

143.0±2.9*

* Uncertainity of the measurement (2% value of flash point) for liquids – flash point between 110 and 200 °C which was determined in validation process.

 

Comment: atmospheric pressure: 1014 hPa

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
24 AUG 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO No., other: 2719: 2007
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup method
Flash point:
149 °C
Atm. press.:
1 014 hPa
Remarks on result:
other: 149.0±3.0 °C (Uncertainity of the measurement)

Results of flash point measurements:

Number of test

Flash point [°C]

1

149.0

2

149.0

The lowest flash point

149.0

Result of determination

149.0±3.0*

* Uncertainity of the measurement (2% value of flash point) for liquids – flash point between 110 and 200 °C which was determined in validation process.

 

Comment: atmospheric pressure: 1014 hPa

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
26 NOV 2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
151 °C
Atm. press.:
101.3 kPa

Description of key information

143 - 151 °C at 1013 - 1014 hPa (ISO 2719, Pensky-Martens closed cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
143 °C

Additional information

The data refer to measurements of substances of various single degrees of ethoxylation (EO = 2 and EO = 1). For a general ethoxylation degree of < 2.5 EO, a weight of evidence approach is applied.