Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: authoritative data base

Data source

Reference
Reference Type:
secondary source
Title:
Substance database of 'Berufsgenossenschaftlichen Instituts für Arbeitsschutz' (BGIA)
Author:
GESTIS
Year:
2007
Bibliographic source:
query date 27 Sep 2007

Materials and methods

Principles of method if other than guideline:
other: measured
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Copper chloride
EC Number:
231-842-9
EC Name:
Copper chloride
Cas Number:
7758-89-6
Molecular formula:
Cl Cu
IUPAC Name:
λ¹-copper(1+) chloride
Details on test material:
Name of test material (as cited in study report): copper chloride
Analytical purity: pure

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
100 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

not combustible

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information