Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.08.2007 - 30.10.2007
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Formula: C12H14ClN5O4
Appearance: White to pale yellow solid
Expiry date: 31 December 2007

Results and discussion

Any other information on results incl. tables

The test substance melted and did not burn. The test substance did not burn over a length of 200 mm within 4 minutes.

The drying loss of the test substance was < 0.1% (dried at 105 °C for 4hours).

Applicant's summary and conclusion

Conclusions:
According to the guideline no further test was performed and the test substance is not classified as "highly flammable".