Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling point
Key result
Boiling pt.:
ca. 305 °C
Atm. press.:
1 027 mBar
Decomposition:
no

Applicant's summary and conclusion

Conclusions:
The test item shows a boiling point of 305°C.