Registration Dossier

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not measured/tested
Remarks:
the test item is liquid
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
all tubes were unchanged

Any other information on results incl. tables

The friction sensitivity was not testet because the test item is a liquid.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item can not be classified as explosive.