Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Compliant, guideline study, available as unpublished report, acceptable without restrictions
Qualifier:
equivalent or similar to
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Key result
Test procedure:
burning time (test type not further specified)
Burning time:
0 s
Remarks on result:
other: Pile failed to ignite during the two minutes that the Bunsen flame was applied..
Test procedure:
ignition time on contact with air
Remarks on result:
no ignition on contact with air (not further specified)

Pile failed to ignite during the two minutes that the Bunsen flame was applied..

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Tetraammineplatinum dichloride is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. Tetraammineplatinum dichloride is not classified as a readily combustible solid under Division 4.1, as it failed to ignite in the preliminary screening test.

Description of key information

Tetraammineplatinum dichloride is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Walker & White (2011) is a GLP compliant study following UN method N1 and is considered suitable for use as the key study for this endpoint. Tetraammineplatinum dichloride is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Justification for classification or non-classification

Based on results from a guideline experimental study, tetraammineplatinum dichloride is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.