Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOWWIN v1.68

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
NCC(=O)NC(CCC(N)=O)C(O)=O

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See information on the model in “Attached justification”.

5. APPLICABILITY DOMAIN
See information on the model in “Attached justification” and information provided in "Overall remarks, attachments" section.

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOWWIN v1.68
- Model description: see information on the model in “Attached justification”.
- Justification of QSAR prediction: see field “Justification for type of information” and “overall remarks”.
GLP compliance:
no
Type of method:
other: QSAR
Partition coefficient type:
octanol-water
Key result
Type:
log Pow
Partition coefficient:
-3.18
Remarks on result:
other: QSAR result, no information on temperature and pH available.

TYPE

NUM

LOGKOW FRAGMENT DESCRIPTION

COEFF

VALUE

Frag

3

-CH2-  [aliphatic carbon]

0.4911

1.4733

Frag

1

-CH    [aliphatic carbon]

0.3614

0.3614

Frag

2

-NH2   [aliphatic attach]

-1.4148

-2.8296

Frag

1

-NH-   [aliphatic attach]

-1.4962

-1.4962

Frag

1

-COOH  [acid, aliphatic attach]

-0.6895

-0.6895

Frag

2

-C(=O)N [aliphatic attach]

-0.5236

-1.0472

Factor

1

C-C(=O)N-C-COOH structure correction

0.4193

0.4193

Factor

1

N-CO-C-N< [C or H attach] correction

0.4

0.4

Const

 

Equation Constant

 

0.229

NOTE: Possible Zwitterion, Neutral Calculation Made

Log Kow = -3.1795

Conclusions:
A log Kow of -3.18 has been calculated by means of a (Q)SAR model (EPI Suite KOWWIN v1.68)
Endpoint:
partition coefficient
Remarks:
Octanol/Water partition coefficient as a function of pH (LogD)
Type of information:
(Q)SAR
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
ACD/Labs Percepta Release 2018.1.1 (Build 3044. 9 Aug 2018)

2. MODEL
LogD

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
NCC(=O)NC(CCC(N)=O)C(O)=O

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See information on the model in “Attached justification”.

5. APPLICABILITY DOMAIN
See information on the model in “Attached justification” and information provided in "Overall remarks, attachments" section.

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: ACD/Labs Percepta Release 2018.1.1 (Build 3044. 9 Aug 2018)
- Model(s) used: LogD
- Model description: see information on the model in “Attached justification”.
- Justification of QSAR prediction: see field “Justification for type of information” and “overall remarks”.
GLP compliance:
no
Type of method:
other: QSAR
Partition coefficient type:
octanol-water
Key result
Type:
log Pow
Partition coefficient:
-5.01
pH:
4
Remarks on result:
other: QSAR result, no information on temperature available.
Key result
Type:
log Pow
Partition coefficient:
-5.13
pH:
7
Remarks on result:
other: QSAR result, no information on temperature available.
Key result
Type:
log Pow
Partition coefficient:
-6.1
pH:
9
Remarks on result:
other: QSAR result, no information on temperature available.

LogD calculated at other pH values:

pH = 1.7 (Stomach): -5.51

pH = 4.6 (Duodenum): -5

pH = 6.5 (Jejunum and Ileum): -5.04

pH = 7.4 (Blood): -5.27

pH = 8.0 (Colon): -5.61

Conclusions:
In the ecological relevant pH range from 4 to 9 the partition coefficient is estimated to be within -5.01 and -6.1 ((Q)SAR model, ACD/Labs Percepta Release 2018.1.1 - LogD model)

Description of key information

Log Pow = -3.18 ((Q)SAR calculation, EPI Suite KOWWIN v1.68)

No information on temperature and pH available.

Key value for chemical safety assessment

Log Kow (Log Pow):
-3.18
at the temperature of:
20 °C

Additional information

The substance is ionizable. The estimated log Pow for the neutral form is supported by LogD calculations (ACD/Labs Percepta Release 2018.1.1 - LogD model) in the ecological relevant pH range from 4 to 9: between -5 and -6.