Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-07-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
1981
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ISO13320-1: Particle Size Analysis - Laser Diffraction Methods
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hessisches Ministerium für Umwelt, ländlichen Raum und Verbraucherschutz, Wiesbaden, Germany
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D10
Mean:
9.4 µm
Remarks on result:
other: st. dev. not reported
Key result
Percentile:
D50
Mean:
27.5 µm
Remarks on result:
other: st. dev. not reported
Key result
Percentile:
D90
Mean:
67.8 µm
Remarks on result:
other: st. dev. not reported

The percentage of particles < 2 µm is < 2.2 % and >=200 µm is < 0.1 %.

The substance consists of rod-shaped crystals.

Conclusions:
The median particle sizes of the test item deduced from the particle size distributions (volumetric) were: L50 = 27.5 μm, L10 = 9.4 μm and L90 = 67.8 μm (ISO 13320, Laser diffraction method)

Description of key information

Median particle sizes: L50 = 27.5 μm, L10 = 9.4 μm and L90 = 67.8 μm (ISO 13320, Laser diffraction method)

Additional information