Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April - June 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Study
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to
Guideline:
EU Method A.6 (Water Solubility)
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
yes (incl. certificate)
Type of method:
column elution method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
XU-18838.00: lot# JHY 1307
Purity: 98.9%

Results and discussion

Water solubility
Water solubility:
< 0.01 mg/L
Temp.:
20 °C
pH:
ca. 6.5

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): insoluble (< 0.1 mg/L)